Instrumentation and Meters

Home » LM Micro Differential Pressure Transmitter

LM Micro Differential Pressure Transmitter

The core component of the LM micro differential pressure transmitter is a capacitive pressure sensing element. It forms a capacitor consisting of a stainless steel diaphragm and a fixed electrode, whose capacitance varies with pressure changes. The sensor sensing element, meticulously designed with the company’s special patented technology, and the unique detection circuit ensure excellent temperature performance and long-term stability.

The LM micro differential pressure transmitter can be used to measure differential pressure or gauge pressure. Its output can be 0-5V, 0-10V, or 4-20mA, and other outputs can also be customized. The MODEL 168 has an accuracy of ±1.0%FS, 0.4%FS, or 0.25%FS at room temperature. The temperature compensation range is -18~+85°C, and the humidity effect is less than ±0.05%FS/°C.

The LM micro differential pressure transmitter offers an excellent performance-to-price ratio and is widely used in fields such as HVAC, environmental pollution control, cleanroom engineering, medical instruments and equipment, oven pressurization and furnace wind pressure control, natural gas and coal gas pipeline network monitoring, underground ventilation, and power plant wind pressure monitoring.

LM 168 Micro Differential Pressure Transmitter Performance Specifications

LM 168 Micro Differential Pressure Transmitter Performance Specifications

Electrical Specifications (Voltage Type)                                                                                                                              Circuit                                            3-wire (+EXC, -EXC, OUTPUT), miswiring protection                                                Power Supply                                 16-32VDC / 16-30VAC (other supply voltages optional)                                              Output                                             0-5VDC, 0-10VDC                                                                                                        Output Impedance                           ≤5.0 OHMS                                                                                                                    *Factory calibration is performed with a 50KΩ load. The 0-5VDC output can operate with a load ≥5KΩ, and the 0-10VDC output can operate with a load ≥10KΩ.                                                                                                                    **Zero Output: Factory set at ±25mV (0-5VDC), ±50mV (0-10VDC)                                                                                    Full Scale Output: Factory set at ±25mV (0-5VDC), ±50mV (0-10VDC)                                                                        Electrical Specifications (Current Type)                                                                                                                            Circuit                                              2-wire (+EXC, -EXC), miswiring protection                                                      Output                                              4-20mA                                                                                                                  Bidirectional Zero Output                12mA                                                                                                                      Power Supply                                   16-32VDC (refer to Figure 2 for the maximum loop resistance)                                External Load                                   0-800 OHM                                                                                                                  *Factory calibration is performed with a 250Ω load and a 24VDC power supply.                                                            **Zero Output: Factory set at ±0.08mA    Full Scale Output: Factory set at ±0.08mA

订货指南

Example: 168W00R1DA1NA represents 0-0.1 in.W.C unidirectional differential pressure, 4-20mA output, 1.0% accuracy, no calibration certificate required, 3/16″ barbed fitting.

LM 186 Micro Differential Pressure Transmitter Performance Specifications

LM 186 Micro Differential Pressure Transmitter Performance Specifications

Electrical Specifications (Voltage Type)                                                                                                                              Circuit                                            3-wire (+EXC, -EXC, OUTPUT), miswiring protection                                                Power Supply                                 16-32VDC / 16-30VAC (other supply voltages optional)                                              Output                                             0-5VDC, 0-10VDC                                                                                                        Output Impedance                           ≤5.0 OHMS                                                                                                                    *Factory calibration is performed with a 50KΩ load. The 0-5VDC output can operate with a load ≥5KΩ, and the 0-10VDC output can operate with a load ≥10KΩ.                                                                                                                    **Zero Output: Factory set at ±25mV (0-5VDC), ±50mV (0-10VDC)                                                                                    Full Scale Output: Factory set at ±25mV (0-5VDC), ±50mV (0-10VDC)                                                                        Electrical Specifications (Current Type)                                                                                                                            Circuit                                              2-wire (+EXC, -EXC), miswiring protection                                                      Output                                              4-20mA                                                                                                                  Bidirectional Zero Output                12mA                                                                                                                      Power Supply                                   16-32VDC (refer to Figure 2 for the maximum loop resistance)                                External Load                                   0-800 OHM                                                                                                                  *Factory calibration is performed with a 250Ω load and a 24VDC power supply.                                                            **Zero Output: Factory set at ±0.08mA    Full Scale Output: Factory set at ±0.08mA

订货指南

Example: 186W00R1DA1NA represents 0~0.1 in.WC unidirectional differential pressure, 4-20mA output, 1% accuracy, no calibration certificate required, 3/16″ barbed fitting.

LM 188 Micro Differential Pressure Transmitter Performance Specifications

LM 188 Micro Differential Pressure Transmitter Performance Specifications

Electrical Specifications (Voltage Type)                                                                                                                              Circuit                                            3-wire (+EXC, -EXC, OUTPUT), miswiring protection                                                Power Supply                                 16-32VDC / 16-30VAC (other supply voltages optional)                                              Output                                             0-5VDC, 0-10VDC                                                                                                        Output Impedance                           ≤5.0 OHMS                                                                                                                    *Factory calibration is performed with a 50KΩ load. The 0-5VDC output can operate with a load ≥5KΩ, and the 0-10VDC output can operate with a load ≥10KΩ.                                                                                                                    **Zero Output: Factory set at ±25mV (0-5VDC), ±50mV (0-10VDC)                                                                                    Full Scale Output: Factory set at ±25mV (0-5VDC), ±50mV (0-10VDC)                                                                        Electrical Specifications (Current Type)                                                                                                                            Circuit                                              2-wire (+EXC, -EXC), miswiring protection                                                      Output                                              4-20mA                                                                                                                  Bidirectional Zero Output                12mA                                                                                                                      Power Supply                                   16-32VDC (refer to Figure 2 for the maximum loop resistance)                                External Load                                   0-800 OHM                                                                                                                  *Factory calibration is performed with a 250Ω load and a 24VDC power supply.                                                            **Zero Output: Factory set at ±0.08mA    Full Scale Output: Factory set at ±0.08mA

订货指南

Example: 188W00R1DA1NA represents 0-0.1 in.WC unidirectional differential pressure, 4-20mA output, 1% accuracy, no calibration certificate required, 3/16″ barbed fitting.

Company Address

A2001-228, Floor 20, R&D Building Phase 4,

International Science and Technology Park,

No. 1355 Jinji Lake Avenue,

Suzhou Industrial Park,

Suzhou, Jiangsu, China

Email​

clara@szyc-materials.com

simon@szyc-materials.com

Whatsapp​

+86 13812870147